Before You Begin

Before performing any shock treatment, it’s recommended that practices routinely test their water quality as part of an overall waterline management program.

Testing provides a baseline and helps verify that your procedures are achieving the desired results over time.

Once you’re ready to proceed, learn how to shock dental waterlines by following the Citrisil™ Shock instructions below.

Step-by-Step: How to Shock Dental Waterlines Using Citrisil™ Shock

Step 1: Empty Water from the Bottle

Remove all water from the self-contained bottle before beginning treatment.

Step 2: Add the Shock Tablet

Drop one Citrisil™ Shock tablet directly into the bottle.

Do not touch the tablet with unprotected skin.

Step 3: Add Water

Add 177 mL (6 fl. oz.) of water to the bottle.

Step 4: Allow the Tablet to Dissolve

Wait at least 60 seconds for the tablet to fully dissolve.

Step 5: Swirl the Solution

Swirl the bottle to clean and treat the inside surfaces of the bottle.

Step 6: Run Solution Through All Waterlines

Connect the bottle to the dental unit and run all waterlines until the orange color appears.

Step 7: Leave Overnight

Allow the solution to remain in all waterlines overnight.

Step 8: Empty the Remaining Solution

The following day, empty any remaining shock solution from the bottle.

Step 9: Flush and Return to Maintenance

Purge the system until the orange color dissipates, then resume treatment with Sterisil’s maintenance product or another EPA-registered antimicrobial designed for dental unit waterlines.

Citrisil Shock Box

Keep Shocking Simple

Shocking your waterlines doesn’t have to be complicated. By following the instructions for use and incorporating monthly shocking into your routine, you can make Shocktober the start of a more consistent waterline maintenance program.

Frequently Asked Questions

Why Is the Solution Orange?

The orange indicator provides a visual confirmation that the shock solution has reached the waterlines during treatment. This simple feature helps users verify that the solution has circulated throughout the system.

Do I Need to Remove My Sterisil® Straw?

No. Citrisil™ Shock is compatible with the Sterisil® Straw, so there is no need to remove the straw or install a dummy straw during treatment.

How Often Should I Shock My Waterlines?

Citrisil™ Shock is designed to be used monthly as part of a comprehensive waterline management protocol.

Can I Resume Patient Care Immediately After Treatment?

After flushing the system and returning to your maintenance protocol, you can resume normal operation according to the IFU and your office procedures.

Blue wavy line
Blue wavy line